  1.  
  2. ─ Area: AIDS-HIV - R ─────────────────────────────────────────────────────────
  3.   Msg#: 505                                          Date: 01-08-93  04:43
  4.   From: Billi Goldberg                               Read: Yes    Replied: No 
  5.     To: All                                          Mark:                     
  6.   Subj: (9) CDC SUMMARY 1/6/93
  7. ──────────────────────────────────────────────────────────────────────────────
  8.  -=> Quoting Billi Goldberg to All <=-
  9.  
  10.  BG> "Rapid HIV Tests: Two for the Price of One" Lancet (12/19-26/92) Vol.
  11.  BG> 340, No. 8834/8835, P. 1541   (Zhang, Xiang et al.)
  12.  BG> Rapid HIV tests can be reused after testing samples that do not  
  13.  BG> contain antibodies to HIV, write Xiang Zhang et al. of the  University
  14.  BG> of Maryland School of Medicine in Baltimore.  Two  panels of 60 HIV 
  15.  BG> confirmed positive and 40 HIV negative sera from individuals in the 
  16.  BG> United States and Central Africa were tested  with two rapid HIV
  17.  BG> assays  immediately after testing of HIV  negative samples by the same
  18.  BG> device.   Assays included the SUDS  (Murex) and Genie (Genetic Systems)
  19.  BG> microparticle filtration  tests.  Both tests incorporate mixtures of 
  20.  BG> viral lysates and  synthetic peptides of HIV, and are done in 10
  21.  BG> minutes  or less.   Both tests accurately detected all HIV positive and
  22.  BG> negative   sera, even though the devices had been used before to test
  23.  BG> HIV  negative  samples.  Also, reactivities were equivalent to those 
  24.  BG> obtained with the  devices used once only.  But the SUDS test  required
  25.  BG> that the reaction  time be extended to 4 minutes rather  than the
  26.  BG> recommended 2 minutes  when testing samples only once.   Each device
  27.  BG> can be used up to five  times (SUDS) with negative  sera and still
  28.  BG> adequately detect positive  sera.  Reusing rapid  test devices provides
  29.  BG> substantial savings,  potentially decreasing the cost by at least half.
  30.  BG> This savings would be  best achieved  when testing samples from a
  31.  BG> low-risk population, in which  most  samples are negative.  However,
  32.  BG> the reuse of cartridges still   requires extra use of kit reagents, and
  33.  BG> will not result in  significant  savings unless excess reagents are
  34.  BG> supplied.  The  performance must be  confirmed with a larger number of
  35.  BG> samples  from both high-risk and low- risk populations before the use
  36.  BG> of  these devices for re-testing can be  considered fully, the 
  37.  BG> researchers conclude. -!-